CE conformitas.
Mensuratio dolor: -100kPa…0kPa~100kPa…70MPa.
● Small Size:φ12.6mm, costae involucrum inferioris.
● Provide OEM, elit elit.
● structura solitaria, pro varietate liquoris mediae pressionis mensurae.
processus industrialis imperium.
● Gas, liquida pressionis mensurae.
● ratio hydraulica.
● Hydrological vigilantia.
● XDB102-6 temperatura & pressionis dual output pressionis sensoris adhiberi potest in systemate hydrau et gas & mensurae pressionis liquidae.
Item | Min. | Typ. | Maximilianus. | Unitates |
Linearity | ±0.15 | ±0.2 | %FS, BFSL | |
Repeatability | ±0.05 | ±0.075 | %FS | |
Hysteresis | ±0.05 | ±0.075 | %FS | |
Nulla output | ±2.0 | ±2.0 | mV DC | |
FS output | 45 | 100 | mV DC | |
Temperatus output | PT100 Resistentia output | |||
Compensat temp. range | 0~70 | C | ||
Laborans temp. range | -40~ 125 | C | ||
Repono temp. range | -55~ 150 | C | ||
Nulla tempor. error | ±0.75 | ± 1.0 | %FS @ 25C | |
Plenus temp. error | ±0.75 | ± 1.0 | %FS@ 25C | |
Longum terminum stabilitatis error | ±0.0 | %FS/year | ||
Nota: 1. Indicatores effectus suprascriptos sub condicione probationis probatae sunt. 2. Temperatura range pro temperatura egisse test est emendatio temperatus range. |
Conditio structura | ||||
Diaphragma materiale | SS 316L | Praesent materia | SS 316L | |
Pin filum | Aurum patella karaf/100mm silicone rubber wire | Retro pressura fistula | SS. | |
sigillum anulum | Nitrile rubber | |||
Electrica conditio | ||||
Potentia copia | 1.5 mA DC | Impedimentum initus | 2.5 kΩ ~ 5 kΩ | |
Impedimentum output | 2.5 kΩ ~ 5 kΩ | Responsio | (10%90%) :<1ms | |
Nulla resistentia | 100MΩ,100V DC | Per pressura | 2 temporibus FS' | |
Environment conditio | ||||
Media applicability | Liquor, qui non mordax est ad ferrum immaculatum et nitrile rubber | Offensus | Nulla mutatio apud 10gRMS, (20~2000) Hz | |
Impact | 100g, 11ms | Position | Declina 90° ab aliqua directione, nulla mutatio ≤±0.05% FS | |
Praecipua conditio | ||||
Mauris tortor | (25±1) | Umor | (50%±10%) RH | |
Atmosphaerae pressura | (86~10) kPa | Potentia copia | (1.5±0.0015) mA DC |
1. Ad sensorem instabilitatem vitandam, quaeso attende ad magnitudinem institutionis et processum institutionis ad vitandum anterius sensorem intra 3 seconds ad vitandum calorem ad sensorem transferendum.
2. Cum bracteolae cotterae clavo uteris in filum, quaeso utere ferrum solidatum infra 25W sub temperatura solida- riorum.
XDB102-6 |
| |||||
| Range code | Mensurae range | Genus pressura | Range code | Mensurae range | Genus pressura |
0B | 0~20kPa | G | 12 | 0~2MPa | G / A | |
0A | 0~35kPa | G | 13 | 0~3.5MPa | G / A | |
02 | 0~70kPa | G | 14 | 0~7MPa | A / S | |
03 | 0~100kPa | G / A | 15 | 0~15MPa | A / S | |
07 | 0~200kPa | G / A | 17 | 0~20MPa | A / S | |
08 | 0~350kPa | G / A | 18 | 0~35MPa | A / S | |
09 | 0~700kPa | G / A | 19 | 0~70MPa | A / S | |
10 | 0~1Mpa | G / A |
|
|
| |
| Code | Genus pressura | ||||
G | Gauge pressura | |||||
A | Pressura absoluta | |||||
S | METIOR signatum pressura | |||||
| Code | Connexio electrica | ||||
1 | Aurum patella kovar pin | |||||
2 | 100mm Silicone Flexilis ducit | |||||
| Code | Aliae species | ||||
Y | Gauge pressura genus potest ad metiretur negans pressura | |||||
XDB102-6 -0B-G-1-Y totum spec |
Ordo notarum
1. Ad sensorem instabilitatem vitandam, quaeso attende ad magnitudinem institutionis et processum institutionis ad vitandum anterius sensorem intra 3 seconds ad vitandum calorem ad sensorem transferendum.
2. Cum bracteolae cotterae clavo uteris in filum, quaeso utere ferrum solidatum infra 25W sub temperatura solida- riorum.